How to use:
VIN connected to the positive of power supply , GND connected to the negative of power supply;
P+ connected to the positive of Motor power supply, P- connected to the negative of Motor power supply;
M + M- are connected to both ends of the motor
After power, D1 flashes 3 times, D2 off, M+ output positive, M- output negative, motor forward; after a time delay T1, D2 on, M+ output negative, M- output positive, motor reversal; after a time delay T2, D2 off, M+ output positive, M- output negativ, motor forward;and so on.
T1: indicates motor Forward delay time, default 0.1-5000 seconds adjustable (step 0.1 seconds)
T2: indicates motor Reverse delay time, default 0.1-5000 seconds adjustable (step 0.1 seconds)
By ``Time multiple selection`` setting,The maximum delay of up to 40,000 seconds
After power, D1 3 blinks, Enter the ``work mode``
D2 on Reversal,D2 Off Forward
Press and hold the Key for 2 seconds,D1 on,enter the ``setup mode``
D2 off, It`s forward ``setup mode``
In forward ``setup mode``, the continuous trigger KEY twice ,D1 off,entry ``Standby timer mode``
In the ``Standby timer mode`` ,trigger KEY start timing(entry ``Timing Mode``)
D1 flashing said it is timing(``Timing Mode``)
Trigger KEY again to stop the clock(exit ``Timing Mode``)
D1 flashing time is forward time(T1)
Press and hold the Key for 2 seconds,D2 on,enter the Reverse ``setup mode``
In Reverse ``setup mode``, the continuous trigger key twice ,D1 off,entry ``Standby timer mode``
In the ``Standby timer mode`` ,trigger KEY start timing(entry ``Timing Mode``)
D1 flashing said it is timing(``Timing Mode``)
Trigger KEY again to stop the clock(exit ``Timing Mode``)
D1 flashing time is Reverse time(T2)
So far, forward time(T1) and reverse time(T2) is set up
Re-power in ``work mode``