![](https://ae01.alicdn.com/kf/Saea7e109000540a0ab5fa9d2f68b97a0N/DC-5V.jpg) ![](https://ae01.alicdn.com/kf/Sf78767883a4c43f4975e63acb3989a72q/DC-5V.jpg) ![](https://ae01.alicdn.com/kf/Sa35894b9319c4fe5bc1e2d7054ed6ff0H/DC-5V.jpg) ![](https://ae01.alicdn.com/kf/S80bdbffe54474289b31cd7b690904263P/DC-5V.jpg) aHR0cDovL2ZyZWVzaGlwLmNvLmty![](https://ae01.alicdn.com/kf/Saea7e109000540a0ab5fa9d2f68b97a0N/DC-5V.jpg) ![](https://ae01.alicdn.com/kf/Sf78767883a4c43f4975e63acb3989a72q/DC-5V.jpg) ![](https://ae01.alicdn.com/kf/Sa35894b9319c4fe5bc1e2d7054ed6ff0H/DC-5V.jpg) ![](https://ae01.alicdn.com/kf/S80bdbffe54474289b31cd7b690904263P/DC-5V.jpg) ![](https://ae01.alicdn.com/kf/Sfd6f3db3e05347d7bc7a82bd71232b6dY/DC-5V.jpg)
- Àü¿ø: DC
- Àü¾Ð: 5v
- ¸ÂÃã °¡´É À¯¹«: ±×·¸½À´Ï´Ù
- »ç¿ë¹ý: ÀÏ¹Ý ¿ëµµ
- ¸ðµ¨ ¹øÈ£: DC 5V Real time Timing Delay Timer Relay Module Switch Control Clock S
- ÄÁÅÃÆ® ·Îµå: ÀúÀü·Â
- º¸È£ ±â´É: Other
- ÀÌ·Ð: ŸÀÓ ¸±·¹ÀÌ
- ºê·£µå À̸§: RQG
- ±Ù¿ø: CN (Á¤Ç°)
Product description
Real-time relay timing and clock synchronization time control delay 24H timing 5 time periods.
Product Highlights:
Wide voltage power supply 5.0V~60V ;
A mode can be set for multiple time periods,can reach 5 time periods;With a buzzer alarm function.
Mode introduction:
OPE:relay closing time point , CLE:relay off time point Time period PE-1-PE-5 5 time periods ( OPE to CLE is a time period)
"----":function shielding
P-1:The relay closes or outputs pulses every day to the OPE time point , and the relay turns off or outputs pulses to the CLE time point .
P-2:set the day , to the OPE time point when the relay closed or output pulse , to the CLE time point when the relay disconnect / or output pulse.
P-3:set the date of the month,to the OPE time point when the relay closed or output pulse,to the CLE time point when the relay is off or output pulse .
P-4:Set the date 1 to date 2 , start every day at the OPE time point , end to the CLE time point , relay action or output pulse .
P-5:As with P-4,only the month can not be set.
Parameter setting
First , how to set the time?
In the time to run the interface , press the DOWN button for a while:
Step 1:Select the time period:PE-1~PE-5 Press UP and DOWN to select;
Step 2: Press the SET key to select the mode : P-1~P-5( Set this time period to the corresponding mode ) by pressing the UP and DOWN keys.("----"means to block this time period).
Note : Each time period can be repeated from the "----",P-1~ P-5 one of the optional ; For example , you can let five time periods at the same time work in the P-1 mode, or let Time period 1 work in P-1 mode,time period 2 work in P-2 mode and so on
Step 3 : After the mode selection is finished , press the SET key to enter the time period setting interface , set the interface in the time period , press the SET key to switch the parameter , "OPE" start time point , "CLE"end point , "dAE" date information;
Step 4 : After setting the parameters to exit the settings ,press the SET button for 2 seconds to release , auto matically check whether the parameter settings are legal , legal to save the parameters , return to the time to run the interface ; if the parameter is wrong , "ERR"eminder ( for example , stop time or Date < = start time or date ) , return to the parameter setting interface;Additional features:Each "time period"can be set individually
In the specific parameter setting intertace ( after the second step ) , press the STOP button to switch the output mode:
OUT1:Start time point turns on the relay , the end time is off the relay;
OUT2: Outputs 1S pulse to start or end time ;
In the specific parameter setting intertace ( after the second step ) , press the STOP button for a while to switch the ringing mode:
BLL0 : Ring disable
BLL1 : Ring enable
Note : When the bell rings , press any button to stop thering.
Extended functions STOP key function expansion : Relay enable mode:
1. ON : enable relay on;
2 .OFF : Do not turn on the relay , it is always off;
Press the STOP button on the time display interface to switch between ON and OFF,the current status will
flash , and then return to the main interface . ( This function is the emergency stop function , press once to close the closed relay)
After the relay is disabled , the product can be used as an alarm clock.
Sleep mode:
1 . C-P sleep mode : within five minutes , without any operation , the digital tube automatically shut down the display , the program normal operation ;
2 . O-d normal mode : digital tube is alwavs open display;Press the STOP button for a while after 2 seconds to release,to achieve C-P and O-d state of the switch , the current state will flash,and then return to the main interface.
Package Included:
1PC * Real-time relay Module ( Note:Not including batteries).
|
|
|
|
|