![](https://ae01.alicdn.com/kf/Sf98c8f60ffe948fc8913447dda71fde8m/GEYA-GYL9-S-RCCB-RCD-ELCB.jpg) ![](https://ae01.alicdn.com/kf/S6028699a457c464fb9849e510dae0291A/GEYA-GYL9-S-RCCB-RCD-ELCB.jpg) ![](https://ae01.alicdn.com/kf/Se9d5be3485a64362b21d11e159eadd36b/GEYA-GYL9-S-RCCB-RCD-ELCB.jpg) ![](https://ae01.alicdn.com/kf/Se9982e133bf54d08b723a891890d9603X/GEYA-GYL9-S-RCCB-RCD-ELCB.jpg) aHR0cDovL2ZyZWVzaGlwLmNvLmty![](https://ae01.alicdn.com/kf/Sf98c8f60ffe948fc8913447dda71fde8m/GEYA-GYL9-S-RCCB-RCD-ELCB.jpg) ![](https://ae01.alicdn.com/kf/S6028699a457c464fb9849e510dae0291A/GEYA-GYL9-S-RCCB-RCD-ELCB.jpg) ![](https://ae01.alicdn.com/kf/Se9d5be3485a64362b21d11e159eadd36b/GEYA-GYL9-S-RCCB-RCD-ELCB.jpg) ![](https://ae01.alicdn.com/kf/Se9982e133bf54d08b723a891890d9603X/GEYA-GYL9-S-RCCB-RCD-ELCB.jpg) ![](https://ae01.alicdn.com/kf/Sdc0cd2860b9b42febf12397c60a59fa82/GEYA-GYL9-S-RCCB-RCD-ELCB.jpg)
- Á¤°Ý Àü¾Ð: 220/380V
- À¯Çü: ȸ·Î Â÷´Ü±â
- ½º¸¶Æ® ±â±â: no
- ¸ÂÃã °¡´É À¯¹«: ±×·¸½À´Ï´Ù
- ¸ðµ¨ ¹øÈ£: GYL9 AC-S Type RCCB
- À¯Çü: ´©Àü Â÷´Ü±â
- ºê·£µå À̸§: GEYA
- ¿ø»êÁö: Áß±¹
- Product Name: GYL9 AC-S Time Delayed RCCB/ELCB
- Voltage: AC230/400V
- Poles: 2P 4P
- Breaking Capacity: 6KA
- Rated Current: 25A 40A 63A 80A 100A
- Rated Sensitivity: 100mA 300mA
- Standard: IEC61008-1
- Rated Frequency: 50/60Hz
- Mounting: Din Rail
Company Information
***It is AC-S type Time Delayed RCCB 2P 4P 40A 63A 100mA/300mA*** Type S (Time-delayed) Type S RCD is a sinusoidal residual current device incorporating a time delay. It can be installed upstream from a Type AC RCD to provide selectivity. A time-delayed RCD cannot be used for additional protection. Where circuits have more than one RCCB, a time delayed unit can be used `upstream` to allow the RCCBs or RCBOs further down the circuit to trip first and avoid nuisance tripping of the whole circuit.
GYL9 earth leakage circuit breaker is suitable to the circuit of AC 50/60Hz.rated voltage 230V for 2 poles and 400V for 4
poles, and rated current up to 100A.when people come across the electric shock or the leakage current of the electrical
network exceeds the fixed value, this product can cut off the fault current in short period so as to protect person and the
equipments, It also can be used in the infrequent starting of the circuit and motors.
The circuit breaker is suitable to industry, commerce, high-rise building, household and other kinds of places.
In complicance with IEC/EN61008-1.
Bilateral busbar wiring capabilities to adapt to the wider use of premises.
Maximum connecting ability of 35mm , wiring torque 3.5N*m, applicable to a variety of installing equipment.
Protection class:IP20.
![GYL9 DATA](https://ae01.alicdn.com/kf/H0cc14d0e7c484be1950aa0239b541b1dL.jpg?width=655&height=723&hash=1378) ![GYL9 DATA2](https://ae01.alicdn.com/kf/H675c6d78a83948dab9fdf6709e73d9a9Z.jpg?width=735&height=394&hash=1129) ![GYL9 DATA3](https://ae01.alicdn.com/kf/Hadd9ed183bee42078049176a2816f185L.jpg?width=824&height=729&hash=1553) ![geya circuit breaker](https://ae01.alicdn.com/kf/H455bb14404d94ee0a9dae34a54564476p.jpg?width=802&height=802&hash=1604)