Packaging Details
- Unit Type:lot (10 pieces/lot)
- Package Weight:1.0kg (2.20lb.)
- Package Size:10cm x 10cm x 10cm (3.94in x 3.94in x 3.94in)
Please note that we are selling factory direct products. All our products are 100% brand new in manufacturer\`s packaging.
Ording Code:
1PC-HE2T(example)
1-) H: Hall Sensor
2-) E: Elbow S: Straight
3-) 2: 1/4\`\` 4: 1/2\`\`
4-) T:Thread P: Plug
Electrical parameters
NO | Item | Examination requirement |
1 | Appearance | Clean and beautiful, smooth without burr, without off color |
2 | Water pressure resistance performance | 1.75 MPa pressure has no slack phenomenon, and parts no crack, relaxation, inflation, and deformation anomaly |
3 | Operating voltage range | DC3-18V |
4 | Maximum operating current | 15mA |
5 | The output pulse high level | In 5 V rated voltage, the output of the high level requirements in 4.5 V above |
6 | The output pulse low level | In 5 V rated voltage, the output of the low level requirements in 0.5 V the following |
7 | The output pulse duty ratio | In the rated voltage, the output pulse occupies emptiescompared to 50%-10% |
8 | Flow pulse characteristics | [4.1Q]±10% |
9 | Insulating property | Dielectric resistance:>100MΩ |
10 | Electrical strength | AC500V 50Hz(Don\`t breakdown or flash winding) |
11 | Electrical strength(100°C) | In 100 °C temperature placed in 72 hours, in the environmental temperature back after 1 hour the accuracy of measurement requirements within the plus or minus 5% |
12 | Cold resistance(-20°C) | In 20 °C temperature placed in-72 hours, in the environmental temperature back after 1 hour the accuracy of measurement requirements within the plus or minus 5% |
13 | Mode of connection | Red: the positive, black: negative, yellow: pulse signal |
![](https://ae01.alicdn.com/kf/HTB1rc_6JVXXXXcYXpXXq6xXFXXX0/120534150/HTB1rc_6JVXXXXcYXpXXq6xXFXXX0.jpg)
1PC-HS2T
![](https://ae01.alicdn.com/kf/UT8FxKzXiRcXXagOFbXk/120534150/UT8FxKzXiRcXXagOFbXk.jpg)
1PC-HS2T
![](https://ae01.alicdn.com/kf/UT8gyOzXhRbXXagOFbX7/120534150/UT8gyOzXhRbXXagOFbX7.jpg)
1PC-HE2PT
![](https://ae01.alicdn.com/kf/UT8Sv1zXa4dXXagOFbXa/120534150/UT8Sv1zXa4dXXagOFbXa.jpg)
1PC-HE2TP
![](https://ae01.alicdn.com/kf/UT8FT9zXgJaXXagOFbXg/120534150/UT8FT9zXgJaXXagOFbXg.jpg)
1PC-HE2T
![](https://ae01.alicdn.com/kf/UT8hauAXghXXXagOFbXc/120534150/UT8hauAXghXXXagOFbXc.jpg)
1PC-HS2P-T
![](https://ae01.alicdn.com/kf/UT8kPezXkNbXXagOFbXn/120534150/UT8kPezXkNbXXagOFbXn.jpg)
1PC-HS2T-P
![](https://ae01.alicdn.com/kf/UT8ngWzXlRcXXagOFbXZ/120534150/UT8ngWzXlRcXXagOFbXZ.jpg)
1PC-HS2T-J
![](https://ae01.alicdn.com/kf/UT8MMizXXJdXXagOFbXL/120534150/UT8MMizXXJdXXagOFbXL.jpg)
The principle of operation
Water flow sensor is the use of the Hall element to measure the Hall effect magnetic sensors
of physical quantities. Water flow sensor mainly consists of copper body, water the rotor assembly,
steady flow component and Hall sensors, installed in the water heater inlet side used to detect the
size and water flow off.
Applications
Mainly used for water heater, boiler, water dispensers, coffee machines, hot card machines,
steam equipment, water system, the campus card sales, selling self-help water systems,
water treatment equipment, cooling systems, mechanical equipment, instrumentation,
pharmaceutical equipment.
Note:
1. When magnetic material is close with the sensor, its characteristics may vary.
2. In order to avoid particle debris, the sensor must be installed after a filter.
3. The flow sensor installation has to avoid strong vibration and shaking of the environment,