ES100G1 VFD
Input :
1> : 1-phase 220V;50/60HZ
2> : 3-phase 220V;50/60HZ
3> : DC200-400V
Output: Voltage : 3 - phase ; 0¢¦240V
ES100G2 VFD
Input :
1> : 3-phase 220V;50/60HZ
2> : 3-phase 220V;50/60HZ
3> : DC200-400V
Output: Voltage : 3 - phase ; 0¢¦240V
ES100G3 VFD
Input :
1> : 3-phase 380-480V;50/60HZ
2> : DC380-700V
Output: Voltage : 3 - phase ; 0¢¦480V
Control Mode :V/F control
Protective Function :Overcurrent, overvoltage, undervoltage, module fault, electric thermal relay, overheat, short circuit,
default phase of input and output, motor parameter adjustment abnormality, internal memory fault, etc.
Control Mode :V/F control
Protective Function :Overcurrent, overvoltage, undervoltage, module fault, electric thermal relay, overheat, short circuit, default phase of input and output, motor parameter adjustment abnormality, internal memory fault, etc.
input voltage Single-phase 220V (0.4-7.5)
Three-phase 220V (0.4-7.5)
Three-phase 380V (0.4-7.5)
Logic input: 4 x1-x4s (Functions: positive and negative rotation, click, multi-segment speed, set terminal UP/DOWN frequency),
Pulse input: Terminal X3 can set pulse input, input range 0-100KHz
Analog input: VI:0-10V/0-20mA (voltage/current signal, modified by dip switch, for frequency given)
Analog output: AMO:0-10V (voltage signal, running frequency, output current indication, etc.)
Relay output: KA/KB/KC one normally open, one normally closed
Control characteristics: V/F control, no PG vector control (sensorless vector control, open loop vector control), can drive asynchronous or synchronous motor (asynchronous synchronous all-in machine)
Built-in PID control (user pressure control, constant output pressure)
Built-in RS485 (for frequency converter status reading, frequency set, frequency converter start stop, etc.)
Built-in 24V power supply
Built-in braking unit 0.75-7.5 (for quick start and quick stop, cutting machine, lifting equipment, etc.)
Permanent magnet synchronization
Safety Precaution:
1.Before installing the inverter ,please read and understand this instruction book.Before connect the inverter,must cut off electricity
2.When the power is cut off, frequency inverter internal may still be residual energy, before handling the inverter electronics,
wait for at least 4 minutes, otherwise there is risk of electric shock.
3.Forbid change any connector on the inverter when power on, in order to avoid the inverter damage and casualties.Inverter earthing terminal,
please be sure to properly grounded
4.Main circuit terminal wiring must be correct, R/L¡¢ S¡¢ T/N as power input terminals, forbid mix with U, V, W output terminals,
or when power on will causes the damage of inverter.
5.Please be sure to follow the manual operation, otherwise may cause serious casualties![](https://ae01.alicdn.com/kf/S8cffaaa708934cb3a2a3db6b1d94cbf0T.jpg)
![](https://ae01.alicdn.com/kf/S92ba9da24502419ab2b56be16e3bc82aY.jpg)
![](https://ae01.alicdn.com/kf/S50e209dafe9b4decb059ccc17e7e36bfH.jpg)
![](https://ae01.alicdn.com/kf/S118159dd7b164f399064e48beea75fd4Z.jpg)
![](https://ae01.alicdn.com/kf/Sa587cd77a1bd4d2eb104f11376c75964p.jpg)
![](https://ae01.alicdn.com/kf/Se6c477296ff1442493cf9b49c3a52e3bY.jpg)
![](https://ae01.alicdn.com/kf/S405523c325b74a1e8e07a43d152d3885F.jpg)
![](https://ae01.alicdn.com/kf/S25e40a35b4b9443bbaa87b54c92fbf022.jpg)
![](https://ae01.alicdn.com/kf/S82d211a0b1ff4cc1a35f7e4b62706f7b1.jpg)