- ¸ðµ¨ ¹øÈ£: CWX-15N
- ¾Ð·Â: Áß°£ ¾Ð·Â
- Àç·á: STAINLESS STEEL
- ±¸Á¶: °ø
- ºê·£µå À̸§: Acarps
- ¿ø»êÁö: Áß±¹
- Rated voltage: AC220V, DC24V, DC12V, ADC9-24V
- Working current: Max150MA
- Maximum power: <5W
- Thread type: NPT
- Working pressure: 1.0Mpa
- Medium temperature: 0-100¡É
- Switching time: <5s
- Output torque: 2NM
- Protection level: lP65
- Control mode: CRO1, CRO2, CRO3, CRO4
Product description 1. The matching structure of POM and metal gear. The POM gear is used in the high-speed stage to reduce gear transmission noise, while the low-speed stage uses metal gears to ensure the reliability of the gear. 2. After the switch is in place, the internal power is automatically cut off, no action, long service life, and the number of switches can reach more than 100,000 times. 3. Integrated design of electrical limit and mechanical limit, high positioning accuracy and consistency, to prevent the possibility of continuous rotation of the actuator. 4. Actuators and valves can be assembled from multiple angles, which is more convenient for space allocation requirements and use. 5. The ball valve adopts a floating seal structure, no leakage, large flow, the valve body is a two-way ball valve, no inlet and outlet ports, suitable for heavy dirt and long-term non-action occasions. 6. Alternatives to solenoid valves-fully open or fully closed to automatically cut off the power; this reduces the possibility of overheating, making it an excellent alternative for projects that need to open the valve for a long time
Scope of application£º Automatic control system, industrial automatic control small equipment, high-efficiency water saving, drinking water equipment, solar hot water project, timing watering, timing humidification, air compressor timing drainage, etc.
Notice: 1. ADC9-24V voltage type can be connected to AC12V, AC24V, DC12V, DC24V 4 voltages
2. The more you order, the more offers, please contact us
3. Package list:1PCS electric Ball Valve
CR01: 2-wire, (positive and negative reverse mode) wiring diagram Voltage: DC12V, DC24V Remarks: SW is a dual control switch 1. SW is connected with OPEN, the valve opens; when in place, the internal power is automatically cut off, and the valve remains in the open state 2. SW is connected with CLOSE, the valve is closed; when in place, the internal power is automatically cut off, and the valve remains in the closed state
CR02: 3-wire, (three-wire two-control mode) wiring diagram Voltage: DC12V, DC24V 1. The SW is connected with OPEN, the valve is opened, and the internal power is automatically cut off when it is in place, and the valve remains in the open state. 2. The SW is connected with CLOSE, the valve is closed, and the internal power is automatically cut off when it is in place, and the valve is kept in the closed state.
CR03: 3-wire, (three-wire one control mode) wiring diagram Voltage: DC12V, DC24V, AC220V, ADC9-24V Remarks: If the power supply is a DC power supply, the red wire needs to be connected to the positive pole, and the green wire needs to be connected to the negative pole. 1. The SW is closed, the valve is opened, and the internal power is automatically cut off when it is in place, and the valve is kept in a fully closed state. 2. The SW is disconnected, the valve is closed, and the internal power is automatically cut off when it is in place, and the valve is kept in a fully closed state.
CR04: 2-wire, (power-off reset mode) wiring diagram Voltage: DC12V, DC24V, AC220V, ADC9-24V Remarks: POWER is an outside connect working power supply, and a farad capacitor is used internally as a backup power supply. The charging time is fast, and it can work in occasions with high switching frequency. 1. SW is connected with OPEN, the valve is opened, and the internal power is automatically cut off when it is in place, and the valve remains in the open state. 2. The SW is connected with CLOSE, the valve is closed, and the internal power is automatically cut off when it is in place, and the valve is kept in the closed state.
|
|
|
|
|